Drives
Drives
-
Part
Part Number
Manufacturer
Description
-
- Siemens 6SL3211-0KB17-5BB1
- 6SL3211-0KB17-5BB1
- Siemens
- SINAMICS G110-CPM110 AC Drive, with integrated filter B 200-240 V 1 AC+10/-10% 47-63 Hz RS-485 interface (USS protocol) CT: 0.75 kW; VT: 0.75 kW CT overload: 150% 60 s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation ambient temperature -10+40 °C without BOP without analog input
-
- Siemens 6SL3211-0KB17-5UA0
- 6SL3211-0KB17-5UA0
- Siemens
- SINAMICS G110, Cpm110 Ac-drive, Without
-
- Siemens 6SL3211-0KB17-5UA1
- 6SL3211-0KB17-5UA1
- Siemens
- SINAMICS G110-CPM110 AC Drive, unfiltered 200-240 V 1 AC+10/-10% 47-63 Hz analog input CT: 0.75 kW; VT: 0.75 kW CT overload: 150% 60 s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation ambient temperature -10+40 °C without BOP without RS-485 interface
-
- Siemens 6SL3211-0KB17-5UB0
- 6SL3211-0KB17-5UB0
- Siemens
- SINAMICS G110 Uss 200v 1ph 0.75kw
-
- Siemens 6SL3211-0KB17-5UB1
- 6SL3211-0KB17-5UB1
- Siemens
- SINAMICS G110-CPM110 AC Drive, unfiltered 200-240 V 1 AC+10/-10% 47-63 Hz RS-485 interface (USS protocol) CT: 0.75 kW; VT: 0.75 kW CT overload: 150% 60 s 150x 90x 101 (HxWxD) IP20; with flat heat sink; only for cooling plate installation ambient temperature -10+40 °C without BOP without analog input
-
- Siemens 6SL3211-1NE17-7AG1
- 6SL3211-1NE17-7AG1
- Siemens
- SINAMICS G120 PM230 Power Module with integrated class A filter degree of protection IP20/PT 380-480 V 3 AC +10/-10% 47-63 Hz power low overload: 3 kW at 150% 3 s, 110% 57 s, 100% 240 s; ambient temperature 0 to +40 °C (LO) 238x 126x 171 (HxWxD), FSA without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 firmware version V4.4 or higher
-
- Siemens 6SL3211-1NE17-7UG1
- 6SL3211-1NE17-7UG1
- Siemens
- SINAMICS G120 PM230 Power Module unfiltered degree of protection IP20/PT 380-480 V 3 AC +10/-10% 47-63 Hz power low overload: 3 kW at 150% 3 s, 110% 57 s, 100% 240 s; ambient temperature 0 to +40 °C (LO) 238x 126x 171 (HxWxD), FSA without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 firmware version V4.4 or higher
-
- Siemens 6SL3211-1NE21-8AG1
- 6SL3211-1NE21-8AG1
- Siemens
- SINAMICS G120 PM230 Power Module with integrated class A filter degree of protection IP20/PT 380-480 V 3 AC +10/-10% 47-63 Hz power low overload: 7.5 kW at 150% 3 s, 110% 57 s, 100% 240 s; ambient temperature 0 to +40 °C (LO) 345x 154x 171 (HxWxD), FSB without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 firmware version V4.4 or higher
-
- Siemens 6SL3211-1NE21-8UG1
- 6SL3211-1NE21-8UG1
- Siemens
- SINAMICS G120 PM230 Power Module unfiltered degree of protection IP20/PT 380-480 V 3 AC +10/-10% 47-63 Hz power low overload: 7.5 kW at 150% 3 s, 110% 57 s, 100% 240 s; ambient temperature 0 to +40 °C (LO) 345x 154x 171 (HxWxD), FSB without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 firmware version V4.4 or higher
-
- Siemens 6SL3211-1NE23-8AG1
- 6SL3211-1NE23-8AG1
- Siemens
- SINAMICS G120 PM230 Power Module with integrated class A filter degree of protection IP20/PT 380-480 V 3 AC +10/-10% 47-63 Hz power low overload: 18.5 kW at 150% 3 s, 110% 57 s, 100% 240 s; ambient temperature 0 to +40 °C (LO) 411x 200x 171 (HxWxD), FSC without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 firmware version V4.4 or higher
-
- Siemens 6SL3211-1NE23-8UG1
- 6SL3211-1NE23-8UG1
- Siemens
- SINAMICS G120 PM230 Power Module unfiltered degree of protection IP20/PT 380-480 V 3 AC +10/-10% 47-63 Hz power low overload: 18.5 kW at 150% 3 s, 110% 57 s, 100% 240 s; ambient temperature 0 to +40 °C (LO) 411x 200x 171 (HxWxD), FSC without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 firmware version V4.4 or higher
-
- Siemens 6SL3211-1NE28-8AL0
- 6SL3211-1NE28-8AL0
- Siemens
- SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20/PT 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 45KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMPERATURE 0 TO +40 DEG C (LO) 411 X 200 X 171 (HXWXD), FSC WITHOUT CONTROL UNIT
-
- Siemens 6SL3211-1NE31-1AL0
- 6SL3211-1NE31-1AL0
- Siemens
- SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20/PT 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMPERATURE 0 TO +40 DEG C (LO) 411 X 200 X 171 (HXWXD), FSC WITHOUT CONTROL UNIT
-
- Siemens 6SL3211-1PB13-8AL0
- 6SL3211-1PB13-8AL0
- Siemens
- SINAMICS Power Module PM240-2 with integrated Class A filter with integrated braking chopper 200-240 V 1/3AC+10/-10% 47-63Hz Power high overload: 0.55kW at 200% 3s, 150% 57s, 100% 240 s; Ambient temperature -10 to +50 °C, power low overload: 0.75kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature -10 to +40 °C 238x 126x 171 (HxWxD), FSA Degree of protection IP20-PT without Control Unit and operating unit Released as of CU firmware version V4.6
-
- Siemens 6SL3211-1PB13-8UL0
- 6SL3211-1PB13-8UL0
- Siemens
- SINAMICS Power Module PM240-2 unfiltered with integrated braking chopper 200-240 V 1/3AC+10/-10% 47-63Hz Power high overload: 0.55kW at 200% 3s, 150% 57s, 100% 240 s; Ambient temperature -10 to +50 °C, power low overload: 0.75kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature -10 to +40 °C 238x 126x 171 (HxWxD), FSA Degree of protection IP20-PT without Control Unit and operating unit Released as of CU firmware version V4.6
-
- Siemens 6SL3211-1PB21-0AL0
- 6SL3211-1PB21-0AL0
- Siemens
- SINAMICS Power Module PM240-2 with integrated Class A filter with integrated braking chopper 200-240 V 1/3AC+10/-10% 47-63Hz Power high overload: 1.5kW at 200% 3s, 150% 57s, 100% 240 s; Ambient temperature -10 to +50 °C, power low overload: 2.2kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature -10 to +40 °C 345x 154x 171 (HxWxD), FSB Degree of protection IP20-PT without Control Unit and operating unit Released as of CU firmware version V4.6
-
- Siemens 6SL3211-1PB21-0UL0
- 6SL3211-1PB21-0UL0
- Siemens
- SINAMICS Power Module PM240-2 unfiltered with integrated braking chopper 200-240 V 1/3AC+10/-10% 47-63Hz Power high overload: 1.5kW at 200% 3s, 150% 57s, 100% 240 s; Ambient temperature -10 to +50 °C, power low overload: 2.2kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature -10 to +40 °C 345x 154x 171 (HxWxD), FSB Degree of protection IP20-PT without Control Unit and operating unit Released as of CU firmware version V4.6
-
- Siemens 6SL3211-1PB21-8AL0
- 6SL3211-1PB21-8AL0
- Siemens
- SINAMICS Power Module PM240-2 with integrated Class A filter with integrated braking chopper 200-240 V 1/3AC+10/-10% 47-63Hz Power high overload: 3kW at 200% 3s, 150% 57s, 100% 240 s; Ambient temperature -10 to +50 °C Power low overload: 4kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature 10 to +40 °C 411x 200x 171 (HxWxD), FSC Degree of protection IP20-PT without Control Unit and operating unit Released as of CU firmware version V4.6
-
- Siemens 6SL3211-1PB21-8UL0
- 6SL3211-1PB21-8UL0
- Siemens
- SINAMICS Power Module PM240-2 unfiltered with integrated braking chopper 200-240 V 1/3AC+10/-10% 47-63Hz Power high overload: 3kW at 200% 3s, 150% 57s, 100% 240 s; Ambient temperature -10 to +50 °C Power low overload: 4kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature -10 to +40 °C 411x 200x 171 (HxWxD), FSC Degree of protection IP20-PT without Control Unit and operating unit Released as of CU firmware version V4.6
-
- Siemens 6SL3211-1PC26-8UL0
- 6SL3211-1PC26-8UL0
- Siemens
- SINAMICS G120 POWER MODULE PM240-2 Push Through, UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC200-240V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMPERATURE -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 18.5kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMPERATURE -20 TO +40 DEG C (LO) 517x275x237 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6
-
- Siemens 6SL3211-1PC31-1UL0
- 6SL3211-1PC31-1UL0
- Siemens
- SINAMICS G120 POWER MODULE PM240-2 Push Through, UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC200-240V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMPERATURE -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 30kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMPERATURE -20 TO +40 DEG C (LO) 615x354x237 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6
-
- Siemens 6SL3211-1PC31-8UL0
- 6SL3211-1PC31-8UL0
- Siemens
- SINAMICS G120 POWER MODULE PM240-2 Push Through, UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC200-240V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMPERATURE -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 55kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMPERATURE -20 TO +40 DEG C (LO) 754x384x358 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6
-
- Siemens 6SL3211-1PE16-1AL0
- 6SL3211-1PE16-1AL0
- Siemens
- SINAMICS G120 POWER MODULE PM240-2 PUSH-THROUGH WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMPERATURE 0 TO +50 DEG C OUTPUT LOW OVERLOAD: 2,2KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMPERATURE 0 TO +40 DEG C 238 X 126 X 171 (HXWXD), FSA PROTECTION IP20/PT WITHOUT CONTROL UNIT AND PANEL
-
- Siemens 6SL3211-1PE18-0AL1
- 6SL3211-1PE18-0AL1
- Siemens
- SINAMICS Power Module PM240-2 with integrated Class A filter with integrated braking chopper 380-480 V 3 AC +10/-10% 47-63 Hz Power high overload: 2.2kW at 200% 3s, 150% 57s, 100% 240 s; Ambient temperature -10 to +50 °C Power low overload: 3kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature -10 to +40 °C 238x 126x 171 (HxWxD), FSA Degree of protection IP20-PT without Control Unit and operating unit Released as of CU firmware version V4.6
-
- Siemens 6SL3211-1PE18-0UL0
- 6SL3211-1PE18-0UL0
- Siemens
- SINAMICS G120 POWER MODULE PM240-2 PUSH-THROUGH WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 2,2KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMPERATURE 0 TO +50 DEG C OUTPUT LOW OVERLOAD: 3KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMPERATURE 0 TO +40 DEG C 238 X 126 X 171 (HXWXD), FSA PROTECTION IP20/PT WITHOUT CONTROL UNIT AND PANEL