Drives
Drives
-
Part
Part Number
Manufacturer
Description
-
- Yaskawa CIMR-AU4T0072UAA
- CIMR-AU4T0072UAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 50HP (Normal duty), Rated output current 72A (Normal duty), frequency (output) 0.01-400Hz, NEMA 12, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0088AAA
- CIMR-AU4T0088AAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 60HP (Normal duty), Rated output current 88A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0088UAA
- CIMR-AU4T0088UAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 60HP (Normal duty), Rated output current 88A (Normal duty), frequency (output) 0.01-400Hz, NEMA 12, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0103AAA
- CIMR-AU4T0103AAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 75HP (Normal duty), Rated output current 103A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0103FAA
- CIMR-AU4T0103FAA
- Yaskawa
- A1000 Series Inverter Drive, Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 75HP (Normal duty), Rated output current 103A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0103UAA
- CIMR-AU4T0103UAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 75HP (Normal duty), Rated output current 103A (Normal duty), frequency (output) 0.01-400Hz, NEMA 12, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0139AAA
- CIMR-AU4T0139AAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 100HP (Normal duty), Rated output current 139A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0139FAA
- CIMR-AU4T0139FAA
- Yaskawa
- A1000 Series Inverter Drive, Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 100HP (Normal duty), Rated output current 139A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0139UAA
- CIMR-AU4T0139UAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 100HP (Normal duty), Rated output current 139A (Normal duty), frequency (output) 0.01-400Hz, NEMA 12, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0165AAA
- CIMR-AU4T0165AAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 125HP (Normal duty), Rated output current 165A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0165FAA
- CIMR-AU4T0165FAA
- Yaskawa
- A1000 Series Inverter Drive, Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 125HP (Normal duty), Rated output current 165A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0165UAA
- CIMR-AU4T0165UAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 125HP (Normal duty), Rated output current 165A (Normal duty), frequency (output) 0.01-400Hz, NEMA 12, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0208AAA
- CIMR-AU4T0208AAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 150HP (Normal duty), Rated output current 208A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0208FAA
- CIMR-AU4T0208FAA
- Yaskawa
- A1000 Series Inverter Drive, Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 150HP (Normal duty), Rated output current 208A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0208UAA
- CIMR-AU4T0208UAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 150HP (Normal duty), Rated output current 208A (Normal duty), frequency (output) 0.01-400Hz, NEMA 12, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0250AAA
- CIMR-AU4T0250AAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 200HP (Normal duty), Rated output current 250A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0250FAA
- CIMR-AU4T0250FAA
- Yaskawa
- A1000 Series Inverter Drive, Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 200HP (Normal duty), Rated output current 250A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0250UAA
- CIMR-AU4T0250UAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 200HP (Normal duty), Rated output current 250A (Normal duty), frequency (output) 0.01-400Hz, NEMA 12, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0296AAA
- CIMR-AU4T0296AAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 250HP (Normal duty), Rated output current 296A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0296UAA
- CIMR-AU4T0296UAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 250HP (Normal duty), Rated output current 296A (Normal duty), frequency (output) 0.01-400Hz, NEMA 12, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0362AAA
- CIMR-AU4T0362AAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 300HP (Normal duty), Rated output current 362A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0362UAA
- CIMR-AU4T0362UAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 300HP (Normal duty), Rated output current 362A (Normal duty), frequency (output) 0.01-400Hz, NEMA 12, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0414AAA
- CIMR-AU4T0414AAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 350HP (Normal duty), Rated output current 414A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0414FAA
- CIMR-AU4T0414FAA
- Yaskawa
- A1000 Series Inverter Drive, Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 350HP (Normal duty), Rated output current 414A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class
-
- Yaskawa CIMR-AU4T0414UAA
- CIMR-AU4T0414UAA
- Yaskawa
- Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) /Inverter, USA region, Yaskawa (A1000 series), Input voltage (6-Phase (6P) 12-pulse) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 350HP (Normal duty), Rated output current 414A (Normal duty), frequency (output) 0.01-400Hz, NEMA 12, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 6-phase 480V class