7SK8052-5EB90-3HD0-L0D
Siemens
Motor protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 changeover contacts) 5 temperature sensors 1 live contact Measuring inputs: Iph = 1 A/5 A, Iee (sensitive) = 0.001 to 1.6 A/0.005 to 8 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) Modbus, electrical RS 485 Without system interface, Port A Measurement: fault recording Mean value formation, min./max. values Functionality: XMZ+ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N: Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>. Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Motor statistics Parameter set switchover Monitoring functions

- 12-month warranty
- Express, worldwide shipping available
- Worldwide shipping
- No hassle returns policy
- Secure payments
- Foxmere is a Google 5-star company
- Google 5-star company
Part Details
Manufacturer
Siemens
Part Number
7SK8052-5EB90-3HD0-L0D
Description
Motor protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 changeover contacts) 5 temperature sensors 1 live contact Measuring inputs: Iph = 1 A/5 A, Iee (sensitive) = 0.001 to 1.6 A/0.005 to 8 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) Modbus, electrical RS 485 Without system interface, Port A Measurement: fault recording Mean value formation, min./max. values Functionality: XMZ+ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N: Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>. Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Motor statistics Parameter set switchover Monitoring functions
Weight
4.00kg
Tarrif Code
85363010
Country of Origin
Germany
Category
Motors & Encoders