- Part Number
- Description
- Availability
-
- 3RK1322-1JS02-0AA0
- AS-i compact starter IP65 Electromechanical DOL starter Setting range 7...10 A AC-3, 4 kW/400 V without brake contact with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1JS02-0AA1
- AS-i compact starter IP65 Electromechanical DOL starter Setting range 7...10 A AC-3, 4 kW/400 V with brake contact 24 V DC/3 A with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1JS02-0AA3
- AS-i compact starter IP65 Electromechanical DOL starter Setting range 7...10 A AC-3, 4 kW/400 V with brake contact 400 V AC with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1JS02-0AA4
- AS-i compact starter IP65 Electromechanical DOL starter Setting range 7...10 A AC-3, 4 kW/400 V With brake contact 500 V DC/1 A with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1JS02-1AA0
- AS-i compact starter IP65 Electromechanical Reversing starter Setting range 7...10 A AC-3, 4 kW/400 V without brake contact with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1JS02-1AA1
- AS-i compact starter IP65 electronic reversing starter Setting range 7...10 A AC-3, 4 kW/400 V with brake contact 24 V DC/3 A with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1JS02-1AA3
- AS-i compact starter IP65 Electromechanical Reversing starter Setting range 7...10 A AC-3, 4 kW/400 V with brake contact 400 V AC with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1JS02-1AA4
- AS-i compact starter IP65 Electromechanical Reversing starter Setting range 7...10 A AC-3, 4 kW/400 V With brake contact 500 V DC/1 A with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1KS02-0AA0
- AS-i compact starter IP65 Electromechanical DOL starter Setting range 9...12 A AC-3, 5.5 kW/400 V without brake contact with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1KS02-0AA1
- AS-i compact starter IP65 Electromechanical DOL starter Setting range 9...12 A AC-3, 5.5 kW/400 V with brake contact 24 V DC/3 A with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1KS02-0AA3
- AS-i compact starter IP65 Electromechanical DOL starter Setting range 9...12 A AC-3, 5.5 kW/400 V with brake contact 400 V AC with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1KS02-0AA4
- AS-i compact starter IP65 Electromechanical DOL starter Setting range 9...12 A AC-3, 5.5 kW/400 V With brake contact 500 V DC/1 A with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1KS02-1AA0
- AS-i compact starter IP65 Electromechanical Reversing starter Setting range 9...12 A AC-3, 5.5 kW/400 V without brake contact with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1KS02-1AA1
- AS-i compact starter IP65 Electromechanical Reversing starter Setting range 9...12 A AC-3, 5.5 kW/400 V with brake contact 24 V DC/3 A with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1KS02-1AA3
- AS-i compact starter IP65 Electromechanical Reversing starter Setting range 9...12 A AC-3, 5.5 kW/400 V with brake contact 400 V AC with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1322-1KS02-1AA4
- AS-i compact starter IP65 Electromechanical Reversing starter Setting range 9...12 A AC-3, 5.5 kW/400 V With brake contact 500 V DC/1 A with 9-pole motor outgoing feeder and 9-pole power connection with 2 integrated inputs
- Available
-
- 3RK1323-2AS51-1AA3
- ECOFAST motor starter AS-Interface mechanical-thermal Reversing starter AC-3, up to 4 kW/400 V with brake contact 400 V AC for internally supplied brakes with 10-pole motor outgoing feeder and 9-pole power connection Plastic enclosure
- Available
-
- 3RK1323-2AS54-1AA0
- Motor starter ECOFAST AS-Interface Mechanical switching thermal overload protection AC-3, 4 kW/400 V 0.30 A...9.00 A without brake contact 2DI 24 V DC Han Q4/2, Han 10E Connection with touch protection
- Available
-
- 3RK1323-2AS54-1AA3
- Motor starter ECOFAST AS-Interface Mechanical switching thermal overload protection AC-3, 4 kW/400 V 0.30 A...9.00 A Brake contact 400 V AC/0.75 A 2DI 24 V DC Han Q4/2, Han 10E Connection with touch protection
- Available
-
- 3RK1323-5BS41-1AA3
- ECOFAST reversing starter AS-Interface Mechanical switching Electronic overload protection AC-3, up to 1.1 kW/400 V 0.30 A...3.00 A Brake contact 400 V AC/0.75 A for internally supplied brakes Digital input DI 2xDC 24 V Enclosure plastic
- Available
-
- 3RK1323-5BS44-3AA0
- Motor starter ECOFAST AS-Interface Mechanical switching Electronic overload protection AC-3, 1.1 kW/400 V 0.30 A...3.00 A without brake contact 4 DI 24 V DC Han Q4/2, Han 10E Connection with touch protection
- Available
-
- 3RK1323-5BS44-3AA3
- Motor starter ECOFAST AS-Interface Mechanical switching Electronic overload protection AC-3, 1.1 kW/400 V 0.30 A...3.00 A Brake contact 400 V AC/0.75 A 4 DI 24 V DC Han Q4/2, Han 10E Connection with touch protection
- Available
-
- 3RK1323-5CS41-1AA3
- ECOFAST reversing starter AS-Interface Mechanical switching Electronic overload protection AC-3, up to 4 kW/400 V 2.40 A...9.00 A Brake contact 400 V AC/0.75 A for internally supplied brakes Digital input DI 2xDC 24 V Enclosure plastic
- Available
-
- 3RK1323-5CS44-3AA0
- Motor starter ECOFAST AS-Interface Mechanical switching Electronic overload protection AC-3, 4 kW/400 V 2.40 A...9.00 A without brake contact 4 DI 24 V DC Han Q4/2, Han 10E Connection with touch protection
- Available
-
- 3RK1323-5CS44-3AA3
- Motor starter ECOFAST AS-Interface Mechanical switching Electronic overload protection AC-3, 4 kW/400 V 2.40 A...9.00 A Brake contact 400 V AC/0.75 A 4 DI 24 V DC Han Q4/2, Han 10E Connection with touch protection
- Available
Trusted by…