Drives
Drives
-
Part
Part Number
Manufacturer
Description
-
- Siemens 7ML5660-3AA00-0JB0
- 7ML5660-3AA00-0JB0
- Siemens
- Pointek Cls300, Digital, Rod Version With Threaded Or Flanged Process Connection: Inverse Frequency Shift Capacitance Level Switch With Optional Rod/cable Choices And Configurable Output. It Is Ideal For Detecting Liquids, Solids, Slurries, Foam
-
- Siemens 7ML5660-3BA00-0CB0
- 7ML5660-3BA00-0CB0
- Siemens
- Pointek Cls300, Digital, Rod Version With Threaded Or Flanged Process Connection: Inverse Frequency Shift Capacitance Level Switch With Optional Rod/cable Choices And Configurable Output. It Is Ideal For Detecting Liquids, Solids, Slurries, Foam
-
- Siemens 7ML5660-3BA00-0JB0
- 7ML5660-3BA00-0JB0
- Siemens
- Pointek Cls300, Digital, Rod Version With Threaded Or Flanged Process Connection: Inverse Frequency Shift Capacitance Level Switch With Optional Rod/cable Choices And Configurable Output. It Is Ideal For Detecting Liquids, Solids, Slurries, Foam
-
- Siemens 7ML5660-6AA00-0JB0
- 7ML5660-6AA00-0JB0
- Siemens
- Pointek Cls300, Digital, Rod Version With Threaded Or Flanged Process Connection: Inverse Frequency Shift Capacitance Level Switch With Optional Rod/cable Choices And Configurable Output. It Is Ideal For Detecting Liquids, Solids, Slurries, Foam
-
- Siemens 7ML5661-5GA10-0HB2
- 7ML5661-5GA10-0HB2
- Siemens
- Pointek Cls300, Digital, Cable Version With Threaded Or Flanged Process Connection: Versatile Inverse Frequency Shift Capacitance Level Switch With Optional Process Connection Choices And Configurable Output, Ideal For Detection Of Liquids, Soli
-
- Siemens 7ML5661-6JA10-0JA2
- 7ML5661-6JA10-0JA2
- Siemens
- Pointek Cls300, Digital, Cable Version With Threaded Or Flanged Process Connection: Versatile Inverse Frequency Shift Capacitance Level Switch With Optional Process Connection Choices And Configurable Output, Ideal For Detection Of Liquids, Soli
-
- Siemens 7ML5662-1DA00-0JB0
- 7ML5662-1DA00-0JB0
- Siemens
- Pointek Cls300, Digital, High Temperature Version With Threaded Or Flanged Process Connection: Inverse Frequency Shift Capacitance Level Switch With Optional Rod/cable Choices And Configurable Output. It Is Ideal For Detecting Liquids, Solids, Slurries
-
- Siemens 7ML5670-1BA00-0AB0
- 7ML5670-1BA00-0AB0
- Siemens
- SITRANS Lc300 Rod Version With Threaded And Flanged Process Connections: An Inverse Frequency Shift Capacitance Continuous Level Transmitter For Liquids And Solids Applications. Process Connection Threaded, 316l (1.4404) Stainless Steel: R 1" ((bs
-
- Siemens 7ML5670-1BA00-0AD0
- 7ML5670-1BA00-0AD0
- Siemens
- SITRANS Lc300 Rod Version With Threaded And Flanged Process Connections: An Inverse Frequency Shift Capacitance Continuous Level Transmitter For Liquids And Solids Applications. Process Connection Threaded, 316l (1.4404) Stainless Steel: R 1" ((bs
-
- Siemens 7ML5670-3BA10-0AB0
- 7ML5670-3BA10-0AB0
- Siemens
- SITRANS Lc300 Rod Version With Threaded And Flanged Process Connections: An Inverse Frequency Shift Capacitance Continuous Level Transmitter For Liquids And Solids Applications. Process Connection Threaded, 316l (1.4404) Stainless Steel: G 1" ((bs
-
- Siemens 7ND4420-1DA16-1AA2
- 7ND4420-1DA16-1AA2
- Siemens
- SIREC DM Display-recorder, Front Dimensi
-
- Siemens 7ND4420-1DA26-1AA2
- 7ND4420-1DA26-1AA2
- Siemens
- SIREC DM Display-recorder, Front Dimensi
-
- Siemens 7ND4420-1PA26-2AD2
- 7ND4420-1PA26-2AD2
- Siemens
- SIREC DM Display-recorder, Front Dimensi
-
- Siemens 7ND4420-4AD16-2AA2
- 7ND4420-4AD16-2AA2
- Siemens
- SIREC DM Display-recorder, Front Dimensi
-
- Siemens 7ND4420-4DC16-1AA2
- 7ND4420-4DC16-1AA2
- Siemens
- SIREC DM Display-recorder, Front Dimensi
-
- Siemens 7RW6000-4EA00-0DA0
- 7RW6000-4EA00-0DA0
- Siemens
- NUMERICAL VOLTAGE, FREQUENCY AND OVEREXCITATION RELAY BINARY INPUT VOLTAGE 24 TO 250V WITH SERIAL RS 485-INTERFACE RATED AUXILIARY VOLTAGE 60/110/125V DC IN 7XP20 CASE FOR PANEL FLUSH MOUNTING OR FOR CUBICLE MOUNTING PRESETTING OF LANGUAGE ENGLISH SCOPE OF FUNCTIONS: VOLTAGE A. FREQUENCY PROTECTION
-
- Siemens 7RW6000-5EA00-0DA0
- 7RW6000-5EA00-0DA0
- Siemens
- NUMERICAL VOLTAGE, FREQUENCY AND OVEREXCITATION RELAY BINARY INPUT VOLTAGE 24 TO 250V WITH SERIAL RS 485-INTERFACE RATED AUXILIARY VOLTAGE 220/250V DC, 115V AC IN 7XP20 CASE FOR PANEL FLUSH MOUNTING OR FOR CUBICLE MOUNTING PRESETTING OF LANGUAGE ENGLISH SCOPE OF FUNCTIONS: VOLTAGE A. FREQUENCY PROTECTION
-
- Siemens 7SD8021-5EB90-1FA1-L0A
- 7SD8021-5EB90-1FA1-L0A
- Siemens
- Line differential protection Enclosure 1/6 19", 4 x I, 7 BI, 8 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km) /multimode fiber (4 km), LC duplex plug Measuring inputs: Iph = 1 A/5 A, Ie = 1 A/5 A Rated auxiliary power: 60 V/110 V/125 V/220 V/250 V DC 115 V/230 V AC Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) PROFIBUS DP slave, electric RS-485 without further communication interface for Port A Measurement: fault recording Functionality Line differential protection Inrush current detection Time-overcurrent protection phase I>, I>>, I>>>, Ip Time-overcurrent protection ground In>. In>>, In>>>, Inp Thermal overload protection Trip circuit monitoring Circuit breaker failure protection Closing lockout Circuit breaker intertrip External trip initiation Parameter set switchover Monitoring functions Circuit breaker test Control of circuit breaker Flexible protection functions Undervoltage/overvoltage V<, V> Underfrequency/overfrequency F<, F> Additional function: Transmission of 16 binary signals (via interface)
-
- Siemens 7SJ6215-5EB32-1FE0
- 7SJ6215-5EB32-1FE0
- Siemens
- MULTI-FUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 8BI, 8BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V TO 230V, TRIGG. LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, 820NM FIBER, ST-PLUG DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS-485 METERING: FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51) : I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N) : IE>, IE>>, IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER/UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE
-
- Siemens 7SJ6221-4EB00-1FE0
- 7SJ6221-4EB00-1FE0
- Siemens
- MULTI-FUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG. LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT METERING: FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51) : I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N) : IE>, IE>>, IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER/UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE
-
- Siemens 7SJ6225-5EB01-3FE0
- 7SJ6225-5EB01-3FE0
- Siemens
- MULTI-FUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V TO 230V, TRIGG. LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, RS-232 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51) : I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N) : IE>, IE>>, IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER/UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE
-
- Siemens 7SJ6225-5EE90-1FE0-L0A
- 7SJ6225-5EE90-1FE0-L0A
- Siemens
- MULTI-FUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V TO 230V, TRIGG. LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE SPANISH, REGION SP, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, RS-485 WITHOUT DIGSI 4/MODEM PORT METERING: FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51) : I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N) : IE>, IE>>, IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER/UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE
-
- Siemens 7SJ6241-4EB00-1FE4
- 7SJ6241-4EB00-1FE4
- Siemens
- MULTI-FUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 4 X U, 4 X I, 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG. LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT METERING: FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51) : I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N) : IE>, IE>>, IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER/UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) SYNCHRONIZATION
-
- Siemens 7SJ6471-5EB91-3FE0-L0S
- 7SJ6471-5EB91-3FE0-L0S
- Siemens
- MULTI-FUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19", 48BI, 21BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V TO 230V, TRIGG. LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, RS-232 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51) : I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N) : IE>, IE>>, IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- Siemens 7SJ8031-5EB00-1FC0
- 7SJ8031-5EB00-1FC0
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITIONAL FUNCTIONS: DRIECTIONAL PHASE & GROUND OVERCURRENT DIRECT. SENSITIVE GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR