Part
Part Number
Manufacturer
Description
-
- Siemens 7SJ8031-5EB90-1FB0 L0D
- 7SJ8031-5EB90-1FB0 L0D
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- Siemens 7SJ8032-5EB00-1FB0
- 7SJ8032-5EB00-1FB0
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- Siemens 7SJ8041-5EB90-1FB0 L0D
- 7SJ8041-5EB90-1FB0 L0D
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- Siemens 7SJ8041-5EB90-1FB0 L0S
- 7SJ8041-5EB90-1FB0 L0S
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- Siemens 7SJ8041-5EB96-3FC1 L0D
- 7SJ8041-5EB96-3FC1 L0D
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS-485 INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITIONAL FUNCTIONS: DRIECTIONAL PHASE & GROUND OVERCURRENT DIRECT. SENSITIVE GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITH AUTOMATIC RECLOSING
-
- Siemens 7SJ8041-5EB96-3FC3 L0R
- 7SJ8041-5EB96-3FC3 L0R
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, ELECTR., DOUBLE, RJ45 CONNECTOR INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITIONAL FUNCTIONS: DRIECTIONAL PHASE & GROUND OVERCURRENT DIRECT. SENSITIVE GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITH AUTOMATIC RECLOSING AND FAULT LOCATOR
-
- Siemens 7SJ8041-5EC90-3FB0-L0S
- 7SJ8041-5EC90-3FB0-L0S
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION US, ANSI, LANGUAGE US-ENGL (LANGUAGE CHANGEABLE) US-FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- Siemens 7SJ8041-5EE06-3FB0
- 7SJ8041-5EE06-3FB0
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI LANGUAGE SPANISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- Siemens 7SJ8042-5ED20-1FB1
- 7SJ8042-5ED20-1FB1
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION FR, IEC/ANSI LANGUAGE FRENCH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC60870-5-103 O. DIGSI4/MODEM ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITH AUTOMATIC RECLOSING
-
- Siemens 7SJ8081-5EB90-1FB0 L0D
- 7SJ8081-5EB90-1FB0 L0D
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- Siemens 7SJ8081-5EB90-1FB0 L0S
- 7SJ8081-5EB90-1FB0 L0S
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR NO SYSTEM PORT A METERING: FAULT RECORDING FUNKTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- Siemens 7SJ8081-5EB90-1FQ0 L0D
- 7SJ8081-5EB90-1FQ0 L0D
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND (50N/51N) : IE>, IE>>, I>>>, IEP, GROUND FAULT PROTECTION IEE>, IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCY PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITIONAL FUNCTIONS: DIRECTIONAL PHASE OVERCURRENT VOLTAGE A. FREQUENCY PROTECTION SYNCHRO-CHECK FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- Siemens 7SJ8082-5EB90-3FC0-L0A
- 7SJ8082-5EB90-3FC0-L0A
- Siemens
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITIONAL FUNCTIONS: DRIECTIONAL PHASE & GROUND OVERCURRENT DIRECT. SENSITIVE GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
-
- ABB 7TCA091300R0218
- 7TCA091300R0218
- ABB
- Xt3gx-xt3gx Module
-
- ABB 7TCA091410R0054
- 7TCA091410R0054
- ABB
- Axw3nc-xw3nc Inverter
-
- Siemens 7VE6110-5EE91-0CB0 L0A
- 7VE6110-5EE91-0CB0 L0A
- Siemens
- NUMERICAL SYNCHRONIZING UNIT CASE 1/3 19", 6BI, 9BO, 1 WATCHDOG CONTACT FLUSH MOUNTING HOUSING SCREW TERMINALS (DIRECT CONNECTION/RING-TYPE CABLE LUGS) SUPPLY VOLTAGE:110V TO 250V DC, 115V TO 230V AC, TRIGG. LEVEL BINARY INPUT 88V DC LANGUAGE SPANISH, 50/60HZ, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, ELECTRICAL RS-485 SERVICE INTERFACE (PORT C) DIGSI 4/MODEM, ELECTRICAL RS-232 SCOPE OF FUNCTIONS: PARALLELING FUNCTION FOR 2 SYNCHRONIZING POINTS 1 1/2-CHANNEL, (SYNCHRO-CHECK WITH 2ND CHANNEL) WITH ADJUSTMENT COMMANDS ADDITIONAL FUNCTION: PROTECTION FUNCTION, NETWORK DECOUPLING FUNCTION, HIGH-PRECISION VOLTAGE AND FREQUENCY PROTECTION, NETWORKDECOUPLING (DF/DT AND VECTORJUMP) WITHOUT ADDITIONAL APPLICATIONS
-
- Siemens 7XT3300-0CA00
- 7XT3300-0CA00
- Siemens
- 20 HZ FREQUENCY GENERATOR FOR EARTH FAULT 100% PROTECTION THE 20HZ FREQUENCY GENERATOR CREATES A 20HZ SQUARE WAVE VOLTAGE WITH AN AMPLITUDE OF APPROX. 25V. THIS VOLTAGE IS CONNECTED VIA BANDPASS AND A LOAD RESISTOR TO THE STATOR CIRCUIT OF THE GENERATOR. THE FREQUENCY GENERATOR IS CONNECT. (THREE PHASE) TO THE VOLTAGE TRANSFORMER. ALTERNATIVELY A POWER SUPPLY VIA THE STATION BATTERY (100,220V DC) IS POSSIB. MAX. POWER CONSUMPT. APPROX.80VA MEASUREMENT VALUE PROCESSING WILL DONE BY 7UM515 IN 7XP20 CASE FOR
-
- Siemens 7XT3400-0CA00
- 7XT3400-0CA00
- Siemens
- 20 HZ BANDPASS FOR STATOR EARTH FAULT 100% PROTECTION THE 20HZ BANDPASS FILTERS THE SQUARE-WAVE VOLTAGE AND TRANS- FORMS IT TO SINUS CURVES WITH FREQUENCIES OF APPROX. 20HZ. THE INTERNAL RESISTANCE IS THEN EQUAL TO APPROX. 8 OHM. AT THE SAME TIME IT PROJECTS THE 20HZ FREQUENCY GENERATOR IN CASE OF EARTH FAULT WITH FULL DISPLACE- MENT VOLTAGE. AT RATED FREQ. THE RESISTANCE IS APPROX. 160 OHM (50HZ), 200 OHM (60HZ). MAX. POWER CONSUMPTION IS APPROX. 80VA. IN 7XP20 CASE FOR FLUSH MOUNTING
-
- Allen-Bradley 80018-303-51-R
- 80018-303-51-R
- Allen-Bradley
- INVERTER GATING CABLE
-
- Allen-Bradley 800T-N29KF4B
- 800T-N29KF4B
- Allen-Bradley
- 30mm Selector Switch 800T Push Button
-
- Allen-Bradley 80190-280-02-R
- 80190-280-02-R
- Allen-Bradley
- Inverter PC board.
-
- Allen-Bradley 80190-380-02-R
- 80190-380-02-R
- Allen-Bradley
- Pkgd Custr Scb-inverter Board.
-
- B&R 80PS080X3.10-01
- 80PS080X3.10-01
- B&R
- Power supply module, Input 3x 380-480 VAC ±10%, Power output 24-80 VDC 16.6 A (max. 1000 W), Output 24 VDC 2 A, X2X Link interface, integrated brake chopper, wall mounting. Order terminal blocks separately!
-
- B&R 80XB120A2.36-00
- 80XB120A2.36-00
- B&R
- 1x lithium battery, 1/2 AA 3.6 V
-
- B&R 80XBR0025.010-11
- 80XBR0025.010-11
- B&R
- Braking resistor for power supply module 80PS080X3.10-01 2.5 Ω 100 W