Motors & Encoders
Motors & Encoders
-
Part
Part Number
Manufacturer
Description
-
- Siemens 7MH7723-1RD
- 7MH7723-1RD
- Siemens
- Motor speed sensor adaptor 182TC 184TC
-
- Siemens 7MH7723-1RE
- 7MH7723-1RE
- Siemens
- Motor speed sensor adaptor 213TC 215TC
-
- Siemens 7MH7723-1RF
- 7MH7723-1RF
- Siemens
- Motor speed sensor adaptor 254TC 256TC
-
- Siemens 7ML1830-1KG
- 7ML1830-1KG
- Siemens
- Motor Assembly, Pls Multivoltage
-
- Siemens 7ML5221-1BC17-Z
- 7ML5221-1BC17-Z
- Siemens
- SITRANS Probe LU Ultrasonic level transmitter: continuous, non-contact, up to 12m (40 ft) range. Monitors level and volume in liquids and slurries. With optional PROFIBUS PA.
-
- Siemens 7ML5745-1BA62-1BA0
- 7ML5745-1BA62-1BA0
- Siemens
- SITRANS LVL100 Vibrating point level switch. Detects level and material in liquids and slurries. Compact, with 40 mm (1.6 inch) insertion. Approvals: ordinary location, CE Version/Process Temperature: Extended -40 to 150 C Process connection: Thread 1" NPT PN64/316L Electronics: Transistor output PNP 10...55 V DC Housing: 316L Electrical connection/Protection: According to ISO4400 including plug/IP65..
-
- Siemens 7ML5745-1CB02-1BA0
- 7ML5745-1CB02-1BA0
- Siemens
- SITRANS LVL100 Vibrating point level switch. Detects level and material in liquids and slurries. Compact, with 40 mm (1.6 inch) insertion. Approvals: ordinary location, CE Version/Process Temperature: Hygienic applications -40 to 150 C Process connection: Tri-Clamp 1 1/2" PN16/316L Ra<0.8 Micrometer Electronics: Transistor output PNP 10...55 V DC Housing: 316L Electrical connection/Protection: According to ISO4400 including plug/IP65..
-
- Siemens 7ML5745-1CB62-1BA0
- 7ML5745-1CB62-1BA0
- Siemens
- SITRANS LVL100 Vibrating point level switch. Detects level and material in liquids and slurries. Compact, with 40 mm (1.6 inch) insertion. Approvals: ordinary location, CE Version/Process Temperature: Hygienic applications -40 to 150 C Process connection: Hygienic fitting with compression nut F40 PN25/316L Ra<0.8 Micrometer Electronics: Transistor output PNP 10...55 V DC Housing: 316L Electrical connection/Protection: According to ISO4400 including plug/IP65..
-
- B&R 7MM424.70-1
- 7MM424.70-1
- B&R
- 2003 motor module, four motor digital output stages, 24 VDC, 3 A to 50°C, max. inrush current 10 A (max. 50 ms), electronic overcurrent and overtemperature protection, order 1x terminal block TB710 separately!
-
- B&R 7MM432.70-1
- 7MM432.70-1
- B&R
- 2003 motor bridge module, two motor (H) bridges, 10 to 30 VDC @ 4 A, peak current up to 8 A (max. 2 s), integrated current controller with electrical overcurrent protection, 12 digital inputs 24 V, optional for use for limit monitoring and position detection (counter functions, 20 kHz A/B/R evaluation), order 1x TB710 and 1x TB718 terminal blocks separately!
-
- B&R 7NC161.7
- 7NC161.7
- B&R
- 2003 encoder module, input frequency 100 kHz, incremental or absolute, 32-bit, encoder power supply 5 VDC or 24 VDC, screw-in module
-
- Siemens 7PV2440-7EN20
- 7PV2440-7EN20
- Siemens
- Solid State Motor Starter
-
- Siemens 7SJ6021-4EB20-1FA0
- 7SJ6021-4EB20-1FA0
- Siemens
- NUMERICAL OVERCURRENT-TIME PROTECTION RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS (4 X I) : IN= 1A SUPPLY VOLTAGE: DC 48 TO 125V TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE EN, DE, FR, ES, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, ELECTRIC RS-485 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP, OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING
-
- Siemens 7SJ6021-5EB00-1FA0
- 7SJ6021-5EB00-1FA0
- Siemens
- NUMERICAL OVERCURRENT-TIME PROTECTION RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS (4 X I) : IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE EN, DE, FR, ES, 50/60HZ IEC/ANSI, REGION WORLD WITHOUT SYSTEM INTERFACE WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP, OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING
-
- Siemens 7SJ6021-5EB30-1FA0
- 7SJ6021-5EB30-1FA0
- Siemens
- NUMERICAL OVERCURRENT-TIME PROTECTION RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS (4 X I) : IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE EN, DE, FR, ES, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, OPTICAL 820NM, ST-PLUG WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP, OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING
-
- Siemens 7SJ6025-5EB00-1HA0
- 7SJ6025-5EB00-1HA0
- Siemens
- NUMERICAL OVERCURRENT-TIME PROTECTION RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS (4 X I) : IN= 5A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE EN, DE, FR, ES, 50/60HZ IEC/ANSI, REGION WORLD WITHOUT SYSTEM INTERFACE WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51) : I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N) : IE>, IE>>, IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECTION (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING
-
- Siemens 7SJ6025-5EB21-1FA0
- 7SJ6025-5EB21-1FA0
- Siemens
- NUMERICAL OVERCURRENT-TIME PROTECTION RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS (4 X I) : IN= 5A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE EN, DE, FR, ES, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, ELECTRIC RS-485 WITH COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP, OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING
-
- Siemens 7SJ6025-5EB21-1HA0
- 7SJ6025-5EB21-1HA0
- Siemens
- NUMERICAL OVERCURRENT-TIME PROTECTION RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS (4 X I) : IN= 5A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE EN, DE, FR, ES, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, ELECTRIC RS-485 WITH COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51) : I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N) : IE>, IE>>, IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECTION (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING
-
- Siemens 7SJ6111-5EB02-1HA0
- 7SJ6111-5EB02-1HA0
- Siemens
- MULTI-FUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 8BI, 8BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V TO 230V, TRIGG. LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS-485 METERING: FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51) : I>, I>>, IP, REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N) : IE>, IE>>, IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECTION (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46) LOCK OUT (86) MOTOR PROTECTION: UNDERCURRENT (37), NEGATIVE SEQUENCE (46), START UP SUPERVERSION (48), START UP BLOCK./LOCKOUT (66/86) WITHOUT AUTO-RECLOSURE
-
- Siemens 7SJ6215-5EE92-3HG0-L0A
- 7SJ6215-5EE92-3HG0-L0A
- Siemens
- MULTI-FUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 8BI, 8BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V TO 230V, TRIGG. LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE SPANISH, REGION SP, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, RS-485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS-485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ DIRECTIONAL TOC+ V/F MOTOR PHASE OVERCURRENT (50/51) : I>, I>>, IP, REVERSE INTERLOCKING, GROUND OVERCURRENT (50N/51N) : IE>, IE>>, IEP, LOCK OUT (86) DIRECTIONAL TIME OVERCURRENT (67/67N WITH 50N/51N) : PHASE ROTATION (47), OVERCURRENT PROTECTION W. 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECTION (50BF) INRUSH BLOCKING, NEGAT. SEQU. (46) MOTOR PROTECTION: UNDERCURR. (37), DIRECTION DETERMINATION FOR OVERCURRENT, PHASES AND EARTH START UP SUPERVERSION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE
-
- Siemens 7SK8012-5EB90-1HD0 L0A
- 7SK8012-5EB90-1HD0 L0A
- Siemens
- Motor protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 changeover contacts) 1 live contact Measuring inputs: Iph = 1 A/5 A, Iee (sensitive) = 0.001 to 1.6 A/0.005 to 8 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) PROFIBUS DP slave, electric RS-485 Without system interface, Port A Measurement: fault recording Functionality: XMZ+ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N: Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>. Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Motor statistics Parameter set switchover Monitoring functions
-
- Siemens 7SK8021-5EB20-1HD0
- 7SK8021-5EB20-1HD0
- Siemens
- Motor protection Enclosure 1/6 19", 4 x I, 7 BI, 8 BO (2 changeover contacts) 1 live contact Measuring inputs: Iph = 1 A/5 A, Ie = 1 A/5 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) IEC60870-5-103 or DIGSI4/modem, electrical RS 485 Without system interface, Port A Measurement: fault recording Functionality: XMZ+ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N: Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>. Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Motor statistics Parameter set switchover Monitoring functions
-
- Siemens 7SK8041-5EB96-3HE0-Z
- 7SK8041-5EB96-3HE0-Z
- Siemens
- Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 7 BI, 8 BO (2 changeover contacts) 1 live contact
-
- Siemens 7SK8042-5EB90-3HE0-L0A
- 7SK8042-5EB90-3HE0-L0A
- Siemens
- Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 7 BI, 8 BO (2 changeover contacts) 1 live contact Measuring inputs: Iph = 1 A/5 A, Iee (sensitive) = 0.001 to 1.6 A/0.005 to 8 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) PROFIBUS DP slave, electric RS-485 Without system interface, Port A Measurement: fault recording Mean value formation, min./max. values Functionality: XMZ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N) Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>, Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Supplementary function: Ground fault direction detection (*)
-
- Siemens 7SK8042-5EB96-1HE0-Z
- 7SK8042-5EB96-1HE0-Z
- Siemens
- Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 7 BI, 8 BO (2 changeover contacts) 1 live contact