Motors & Encoders
Motors & Encoders
-
Part
Part Number
Manufacturer
Description
-
- Siemens 7SK8042-5EB96-3HE0
- 7SK8042-5EB96-3HE0
- Siemens
- Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 7 BI, 8 BO (2 changeover contacts) 1 live contact
-
- Siemens 7SK8042-5EB96-3HE0-L0A
- 7SK8042-5EB96-3HE0-L0A
- Siemens
- Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 7 BI, 8 BO (2 changeover contacts) 1 live contact Measuring inputs: Iph = 1 A/5 A, Iee (sensitive) = 0.001 to 1.6 A/0.005 to 8 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) PROFIBUS DP slave, electric RS-485 Interface, Port A (device underside, front) With Ethernet interface (DIGSI interface, thermobox connection, not IEC61850) RJ45 connector Measurement: fault recording Mean value formation, min./max. values Functionality: XMZ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N) Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>, Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Supplementary function: Ground fault direction detection (*)
-
- Siemens 7SK8052-5EB90-3HD0-L0D
- 7SK8052-5EB90-3HD0-L0D
- Siemens
- Motor protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 changeover contacts) 5 temperature sensors 1 live contact Measuring inputs: Iph = 1 A/5 A, Iee (sensitive) = 0.001 to 1.6 A/0.005 to 8 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) Modbus, electrical RS 485 Without system interface, Port A Measurement: fault recording Mean value formation, min./max. values Functionality: XMZ+ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N: Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>. Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Motor statistics Parameter set switchover Monitoring functions
-
- Siemens 7SR1101-1JA12-1CA0
- 7SR1101-1JA12-1CA0
- Siemens
- ARGUS-C NON DIRECT. OVERCURRENT RELAY 1 CT, 10 LEDS, 3 BINARY INPUTS/5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ 24 to 60 V DC auxiliary, binary input threshold 19 V DC. USB FRONT PORT, RS-485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER: NO PUSH BUTTONS PROTECTION FUNCTION: STANDARD VERSION
-
- Siemens 7SR1102-1JA12-1CA0
- 7SR1102-1JA12-1CA0
- Siemens
- ARGUS-C NON DIRECT. OVERCURRENT RELAY 4 CT, 10 LEDS, 3 BINARY INPUTS/5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ 24 to 60 V DC auxiliary, binary input threshold 19 V DC. USB FRONT PORT, RS-485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER: NO PUSH BUTTONS PROTECTION FUNCTION: STANDARD VERSION
-
- Siemens 7SR1103-1MA12-1CA0
- 7SR1103-1MA12-1CA0
- Siemens
- ARGUS-C NON DIRECT. OVERCURRENT RELAY 4 CT, 10 LEDS, 6 BINARY INPUTS/8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 24 TO 250V DC, 100 TO 230V AC, BINARY INPUT THRESHOLD 19V DC. USB FRONT PORT, RS-485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER: NO PUSH BUTTONS PROTECTION FUNCTION: STANDARD VERSION
-
- Siemens 7SR1206-2MA12-1CA0
- 7SR1206-2MA12-1CA0
- Siemens
- ARGUS-C DIRECTIONAL OVERCURRENT RELAY 4 CT, 3 VT, 10 LEDS, 6 BINARY INPUTS/8 BINARY OUTP. MEASURING INPUT: 1/5A, 40 to 160V, 50/60HZ DC, 100 TO 230V AC, BINARY INPUT THRESHOLD 19V DC. USB FRONT PORT, RS-485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER: NO PUSH BUTTONS PROTECTION FUNCTION: STANDARD VERSION
-
- Siemens 7SR1208-4NA12-2CA0
- 7SR1208-4NA12-2CA0
- Siemens
- ARGUS-C DIRECTIONAL OVERCURRENT RELAY 4 CT, 3 VT, 10 LEDS, 4 BINARY INPUTS/8 BINARY OUTP. MEASURING INPUT: 1/5A,40 to 160V, 50/60HZ WITH SEF INPUT DC, 100 TO 230V AC, BINARY INPUT THRESHOLD 88V DC. USB FRONT PORT, RS-485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER: PUSH BUTTONS, DOWN AND RIGHT ARROWS PROTECTION FUNCTION: STANDARD VERSION
-
- Siemens 7SR1703-3MA87-1CA0
- 7SR1703-3MA87-1CA0
- Siemens
- MOTOR PROTECTION RELAY (RHO) CT, 6 BINARY INPUTS/8 BINARY OUTPUTS, 10 LEDs MEASURING INPUT: 1/5A, 50/60HZWITH SEF INPUT Auxiliary voltage: 24 to 250 V DC, 100 to 230 V AC, binary input threshold 19 V DC. REAR OPTICAL ETHERNET DUPLEX (E6 CASE iIS REQUIRED) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 AND IEC 61850 OR MODBUS RTD CLIENT (USER SELECTABLE SETTING) FRONT COVER: NO PUSH BUTTONS PROTECTION FUNCTION: STANDARD VERSION
-
- Siemens 7SR2302-1MA77-0CA0
- 7SR2302-1MA77-0CA0
- Siemens
- HIGH IMPEDANCE PROTECTION RELAY CIRCULATING CURRENT (4 POLE FUNCTIONALITY) E6 CASE, 4 CT, 8 LEDS, 9 BINARY INPUTS/8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 24, 250V DC/100-230V AC BINARY INPUT THRESHOLD 19V DC (RATED: 24-250V DC). USB FRONT PORT, RS-485 REAR PORT + REAR ELECTRICAL ETHERNET RJ45 PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) AND IEC61850. PROTECTION FUNCTION: 3 PHASE HIGH IMPEDANCE DIFFERENTIAL (87/50) HIGH IMPEDANCE RESTRICTED EARTH FAULT (87REF) MEASURED EARTH FAULT (50G) 3 PHASE CT SUPERVISION (CT50) TRIP CIRCUIT SUPERVISIOR (74TC) PROGRAMMABLE LOGIC..
-
- Siemens 7SR4501-1GA10-1AA0
- 7SR4501-1GA10-1AA0
- Siemens
- ARGUS Non-directional overcurrent-time protection Polycarbonate enclosure, 4x current transformer, 2 BI/2 BQ, pulse output, 9 LEDs Measuring input: 1 A, 50/60Hz Auxiliary voltage: current transformer supplied USB front interface No protocol (no interface on the rear) Device front: standard version Protection function package: basic version
-
- Siemens 7SR5111-7AA16-0AA0
- 7SR5111-7AA16-0AA0
- Siemens
- Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 39 BI, 20 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
-
- Siemens 7SR5421-1AA16-0AA0
- 7SR5421-1AA16-0AA0
- Siemens
- Transformer protection (2 wdg.) 8 curr. trans., 4 volt. trans. 12 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
-
- Siemens 7UT6121-5EB00-1AA0
- 7UT6121-5EB00-1AA0
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM. BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURRENT PROTECTIONTOC PHASE (50/51) : I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURRENT PROTECTIONTOC 3I0 (50/51) : 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURRENT PROTECTIONTOC EARTH (50/51) : IE>, IEE>>, IEP (INRUSH BLOCKING)
-
- Siemens 7UT6121-5EB30-1BA0
- 7UT6121-5EB30-1BA0
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM. BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, 820NM FIBER, ST-PLUG, WITHOUT DIGSI 4/MODEM PORT BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ, 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N WITHOUT RESISTOR AND VARISTOR) SENSITIVE OVERCURRENT-TIME PROTECTION/TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECTION (46) BREAKER FAILURE PROTECTION (50BF) TRIP CIRCUIT SUPERVISION (74TC)
-
- Siemens 7UT6121-5EB90-1BA0
- 7UT6121-5EB90-1BA0
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY. FOR TRANSFORMER. GENERATORS. MOTOR AND SHORT CABLE 4-LINE ALPHANUM. BACKLIT DISPLAY 7 PROGRAMMABLE LED. NAVIGATION KEYS. FUNCTION KEYS. CASE 1/3 X 19". 3BI. 4BO. 1 WATCHDOG CONTACT. 7I. IEE.
-
- Siemens 7UT6121-5EB91-1BA0 L0D
- 7UT6121-5EB91-1BA0 L0D
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM. BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B MODBUS, RS-485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, BROWSER, ELECTRIC. RS-232 BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ, 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N WITHOUT RESISTOR AND VARISTOR) SENSITIVE OVERCURRENT-TIME PROTECTION/TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECTION (46) BREAKER FAILURE PROTECTION (50BF) TRIP CIRCUIT SUPERVISION (74TC)
-
- Siemens 7UT6121-5EB92-1BA0-L0S
- 7UT6121-5EB92-1BA0-L0S
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM. BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET, WITH INTEGRATED SWITCH, OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS-485 BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ, 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N WITHOUT RESISTOR AND VARISTOR) SENSITIVE OVERCURRENT-TIME PROTECTION/TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECTION (46) BREAKER FAILURE PROTECTION (50BF) TRIP CIRCUIT SUPERVISION (74TC)
-
- Siemens 7UT6131-2BB11-1AA0
- 7UT6131-2BB11-1AA0
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM. BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 24V TO 48V, TRIGGER LEVEL BINARY INPUT 19V REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS-232, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, BROWSER, ELECTRIC. RS-232 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURRENT PROTECTIONTOC PHASE (50/51) : I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURRENT PROTECTIONTOC 3I0 (50/51) : 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURRENT PROTECTIONTOC EARTH (50/51) : IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDITIONAL VOLTAGE FUNCTION WITHOUT ADDITIONAL FUNCTIONS
-
- Siemens 7UT6131-5EB22-1AA0
- 7UT6131-5EB22-1AA0
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM. BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS-485, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS-485 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURRENT PROTECTIONTOC PHASE (50/51) : I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURRENT PROTECTIONTOC 3I0 (50/51) : 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURRENT PROTECTIONTOC EARTH (50/51) : IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDITIONAL VOLTAGE FUNCTION WITHOUT ADDITIONAL FUNCTIONS
-
- Siemens 7UT6135-4EC92-4AA0-L0S
- 7UT6135-4EC92-4AA0-L0S
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM. BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, CURRENT TRANSFORMER: 5A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION US, IEC/ANSI, LANGUAGE US-ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS-485 BASIS MEASURED VALUES, FAULT RECORDING + MEAN VALUES, MIN/MAX VALUES + TRANSFORMER-MONITORING FUNCTION (CONNECTION ON THERMO-BOX, HOTSPOT IEC345, OVERLOAD FACTOR) FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURRENT PROTECTIONTOC PHASE (50/51) : I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURRENT PROTECTIONTOC 3I0 (50/51) : 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURRENT PROTECTIONTOC EARTH (50/51) : IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDITIONAL VOLTAGE FUNCTION WITHOUT ADDITIONAL FUNCTIONS
-
- Siemens 7UT6135-5EB22-1BA0
- 7UT6135-5EB22-1BA0
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM. BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, CURRENT TRANSFORMER: 5A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS-485, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS-485 BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ, 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N WITHOUT RESISTOR AND VARISTOR) SENSITIVE OVERCURRENT-TIME PROTECTION/TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECTION (46) BREAKER FAILURE PROTECTION (50BF) TRIP CIRCUIT SUPERVISION (74TC) WITHOUT ADDITIONAL VOLTAGE FUNCTION WITHOUT ADDITIONAL FUNCTIONS
-
- Siemens 7UT6135-5EE92-1BC1-L0R
- 7UT6135-5EE92-1BC1-L0R
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM. BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, CURRENT TRANSFORMER: 5A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, EC/ANSI, LANGUAGE SPANISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET DOUBLE, ELECTRICAL, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS-485 BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ, 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N WITHOUT RESISTOR AND VARISTOR) SENSITIVE OVERCURRENT-TIME PROTECTION/TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECTION (46) BREAKER FAILURE PROTECTION (50BF) TRIP CIRCUIT SUPERVISION (74TC) ADDITIONAL FUNCTION: VOLTGAE MEASUREMENT AND OVEREXCITATION PROTECTION, OVER-/UNDERVOLTAGE PROTECTION, FREQUENCY PROTECTION, DIRECTIONAL PROTECTION, FUSE FAILURE MONITOR MULTIPLE PROTECTION FUNCTION XMZ (50,51,50N/G,51N/G), REF (87N), SVS (50BF), ULS (49)
-
- Siemens 7UT6331-5EB02-1AA0
- 7UT6331-5EB02-1AA0
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 21BI, 24BO, 1 WATCHDOG CONTACT, 11I, IEE, 4 VOLTAGE INPUTS (1 X 3-PHASE + 1 X 1-PHASE) CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS-485 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURRENT PROTECTIONTOC PHASE (50/51) : I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURRENT PROTECTIONTOC 3I0 (50/51) : 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURRENT PROTECTIONTOC EARTH (50/51) : IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDITIONALVOLTAGE FUNCTIONS WITHOUT ADDITIONAL FUNCTIONS
-
- Siemens 7UT6331-5EB02-1BB0
- 7UT6331-5EB02-1BB0
- Siemens
- DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 21BI, 24BO, 1 WATCHDOG CONTACT, 11I, IEE, 4 VOLTAGE INPUTS (1 X 3-PHASE + 1 X 1-PHASE) CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS-485 BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ, 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N WITHOUT RESISTOR AND VARISTOR) SENSITIVE OVERCURRENT-TIME PROTECTION/TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECTION (46) BREAKER FAILURE PROTECTION (50BF) TRIP CIRCUIT SUPERVISION (74TC) ADDITIONAL FUNCTION: VOLTAGE MEASUREMENT AND OVEREXCITATION PROTECTION WITHOUT ADDITIONAL FUNCTIONS