Motors & Encoders
Motors & Encoders
-
Part
Part Number
Manufacturer
Description
-
- Yaskawa VZAB-0P2-BAA
- VZAB-0P2-BAA
- Yaskawa
- Drive, rated at 0.25KW, 1.6A, 200V.
-
- Allen-Bradley W-3016-N-H00AA
- W-3016-N-H00AA
- Allen-Bradley
- H-Series servo motor, 3-inch frame.
-
- Allen-Bradley W-3016-N-H00AB
- W-3016-N-H00AB
- Allen-Bradley
- H-Series servo motor, 3-inch frame.
-
- Allen-Bradley W-4030-M-H00AA
- W-4030-M-H00AA
- Allen-Bradley
- H-Series servo motor, 4-inch frame.
-
- Allen-Bradley W-4030-M-H00AB
- W-4030-M-H00AB
- Allen-Bradley
- H-Series servo motor, 4-inch frame.
-
- Allen-Bradley W-4030-P-H00AA
- W-4030-P-H00AA
- Allen-Bradley
- H-Series servo motor, 4-inch frame.
-
- Allen-Bradley W-4030-P-H00AB
- W-4030-P-H00AB
- Allen-Bradley
- H-Series servo motor, 4-inch frame.
-
- Allen-Bradley W-4050-P-H00AA
- W-4050-P-H00AA
- Allen-Bradley
- H-Series servo motor, 4-inch frame.
-
- Allen-Bradley W-4050-P-H00AB
- W-4050-P-H00AB
- Allen-Bradley
- H-Series servo motor, 4-inch frame.
-
- Allen-Bradley W-4075-R-H00AA
- W-4075-R-H00AA
- Allen-Bradley
- H-Series servo motor, 4-inch frame.
-
- Allen-Bradley W-4075-R-H00AB
- W-4075-R-H00AB
- Allen-Bradley
- H-Series servo motor, 4-inch frame.
-
- Siemens W2D155-EA08-01
- W2D155-EA08-01
- Siemens
- Axial fan servo motor rated at 400 V.
-
- Pepperl+Fuchs WCS2B-LS146
- WCS2B-LS146
- Pepperl+Fuchs
- Encoder Read Head
-
- Pepperl+Fuchs WCS2B-LS211
- WCS2B-LS211
- Pepperl+Fuchs
- Encoder
-
- Pepperl+Fuchs WCS3B-LS310D
- WCS3B-LS310D
- Pepperl+Fuchs
- Encoder With Display
-
- Pepperl+Fuchs WCS3B-LS510
- WCS3B-LS510
- Pepperl+Fuchs
- Read Head, Ethernet/ip Interface, Non Contact Absolute Position Encoder, M12 8 Pin Connector
-
- B&R X20cCM0985-1
- X20cCM0985-1
- B&R
- The module has a compact size and combines a power measurement module that has special features with a synchronization unit that is able to meet all demands. The measurement unit's 3 current inputs are suitable for both X: 1 A and X: 5 A current transformers. Overcurrent resistance and the high resolution of the measurement unit round off its features. For the voltage inputs, the value range can be configured between 480 VAC and 120 VAC. The area of use includes 4-wire AC networks with a phase voltage up to 480 VAC and 3-wire systems, whereas L2 can be grounded (V-connection). The module can also handle Aron measuring circuits. The resulting measured values include the pure phase current; line-to-line voltage or phase voltage; the effective, reactive and apparent power parts; the mains frequency; the power factor and much more. In addition, peak values and energy meters are stored on the module in nonvolatile memory. Depending on the configuration, it is also possible to use a digital output as a pulse encoder for an external energy meter. The synchronization unit doesn't just take the phasing and phase voltage into consideration; integrated intelligence also monitors the rate of change and other parameters, allowing them to influence when the synchronization output is switched. It is also possible to monitor a generator using a large number of additional conditions. A total of 4 voltage inputs provide substantial overall flexibility. Monitoring functions expand the features of the module. Dependent overcurrent monitoring is included, which utilizes the thermal capacity of the motor/generator to allow short overloads while still providing full protection. The dependent, delayed imbalanced load monitoring used to protect three-phase generator and three-phase networks from imbalanced load can be adapted to the characteristics of different generator types using parameters while taking their special thermal time constants into account.
-
- B&R X20cDC1196
- X20cDC1196
- B&R
- The module is equipped with 1 input for an ABR incremental encoder with 5 V encoder signal.
-
- B&R X20cDC1198
- X20cDC1198
- B&R
- This module is equipped with one input for SSI absolute encoders with 5 V encoder signal.
-
- B&R X20cDC1396
- X20cDC1396
- B&R
- The module is equipped with 1 input for an ABR incremental encoder with 24 V encoder signal.
-
- B&R X20cDC2395
- X20cDC2395
- B&R
- This module is a multifunctional counter module. It can be connected to one SSI encoder, one ABR encoder, two AB encoders or four event counters. Two outputs are available for pulse width modulation. The functions can also be mixed.
-
- B&R X20cDI4760
- X20cDI4760
- B&R
- The module is used to transfer digital signals from NAMUR encoders according to EN 60947-5-6. In addition to NAMUR encoders, normal switches can also be used.
-
- B&R X20cDS1119
- X20cDS1119
- B&R
- This module is a multifunction digital signal processor module. It can be used extremely flexibly for a wide variety of tasks involving digital signal processing or digital signal generation. Two primary example applications include controlling stepper output stages with pulse and direction signals or using as encoder emulation. In this application, for example, frequency inverters or servo axes with the speed follow function can follow a real or virtual master axis. An additional major feature is the module's integrated timestamp function. It allows counter ramps curves to be generated virtually independently of bus cycle times during encoder emulation, for example. Only the target counter value and moment when it should be reached are transferred. The module automatically generates the corresponding counter values at the appropriate time, precisely in microsecond resolution and independently of the bus clock.
-
- B&R X20CM0985
- X20CM0985
- B&R
- The module has a compact size and combines a power measurement module that has special features with a synchronization unit that is able to meet all demands. The measurement unit's 3 current inputs are suitable for both X: 1 A and X: 5 A current transformers. Overcurrent resistance and the high resolution of the measurement unit round off its features. For the voltage inputs, the value range can be configured between 480 VAC and 120 VAC. The area of use includes 4-wire AC networks with a phase voltage up to 480 VAC and 3-wire systems, whereas L2 can be grounded (V-connection). The module can also handle Aron measuring circuits. The resulting measured values include the pure phase current; line-to-line voltage or phase voltage; the effective, reactive and apparent power parts; the mains frequency; the power factor and much more. In addition, peak values and energy meters are stored on the module in nonvolatile memory. Depending on the configuration, it is also possible to use a digital output as a pulse encoder for an external energy meter. The synchronization unit doesn't just take the phasing and phase voltage into consideration; integrated intelligence also monitors the rate of change and other parameters, allowing them to influence when the synchronization output is switched. It is also possible to monitor a generator using a large number of additional conditions. A total of 4 voltage inputs provide substantial overall flexibility. Monitoring functions expand the features of the module. Dependent overcurrent monitoring is included, which utilizes the thermal capacity of the motor/generator to allow short overloads while still providing full protection. The dependent, delayed imbalanced load monitoring used to protect three-phase generator and three-phase networks from imbalanced load can be adapted to the characteristics of different generator types using parameters while taking their special thermal time constants into account.
-
- B&R X20CM0985-02
- X20CM0985-02
- B&R
- The module combines a power measurement module with special features in a compact footprint together with a synchronizing unit that meets all requirements. The measurement unit is 3 current inputs are suitable for both X: 1 A and X: 5 A current transformers. Overcurrent resistance and the high resolution of the unit of measurement round off its features. For the voltage inputs, the value range can also be configured between 480 VAC and 120 VAC without any loss in converter resolution. The area of application includes 4-wire AC power systems with a line-to-line voltage up to 480 VAC and 3-wire systems, where L2 can be grounded (V circuit). In addition, the module masters the measuring principle of the Aron circuit. The resulting measured values range from the pure phase current and line-to-line or phase voltage to active, reactive and apparent power components, mains frequency, power factor and much more. In addition, peak values and energy meters are stored on the module in nonvolatile memory. Depending on the configuration, it is also possible to use a digital output as a pulse encoder for an external energy meter. The synchronization unit does not just take the phasing and phase voltage into consideration; integrated intelligence also monitors the rate of change and other parameters, allowing them to influence when the synchronization output is switched. It is also possible to monitor a generator using a large number of additional conditions. A total of 4 voltage inputs provide substantial overall flexibility. Monitoring functions expand the features of the module. Dependent overcurrent monitoring is included, which utilizes the thermal capacity of the motor/generator to allow short overloads while still providing full protection. The dependent, delayed imbalanced load monitoring used to protect three-phase generator and three-phase networks from imbalanced load can be adapted to the characteristics of different generator types using parameters while taking their special thermal time constants into account.